Now ask about our full range of products and services.
Electric high-pressure regulating valve
Consists of the 3810L series linear electric actuator and the high-pressure regulating valve body of the PSL series. Electric high-pressure cage regulator is a product developed for high-pressure or high-pressure differential valve, severe cavitation, erosion under harsh working conditions, short service life, easily broken valve stem, and easy liner fall off. The electric high pressure control valve adopts cage type throttling to apportion pressure difference, reducing cavitation erosion, erosion and flexing flow damage, and greatly improving the service life of the regulating valve, especially for use in the urea system. 3 times. The electric actuator is an integrated structure with a servo amplifier. The input control signal (4~20mADCor1~5VDC) and the power supply can control the opening of the valve to achieve the adjustment of the parameters such as pressure, flow, liquid level and temperature. The valve body is straight-through, the valve core is a single-guided structure, the valve body flow path is simple, and the resistance is small. The electric high-pressure regulating valve is particularly suitable for high viscosity, containing suspended solids and granular medium fluid adjustment, can avoid coking, bonding, Blocked. The electric high-pressure regulating valve has the characteristics of agile movement, simple connection, large flow, small size and high adjustment accuracy.
Nominal diameter(DN) | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 | |
Valve seat diameter(dn) | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 | |
Rated flow coefficient(KV) |
sleeve | 6.9 | 11 | 17.6 | 27.5 | 44 | 69 | 110 | 176 | 275 | 440 | 630 | 875 | 1250 |
Cage Type | 6.3 | 10 | 16 | 25 | 40 | 63 | 100 | 155 | 250 | 370 | 580 | 900 | 1300 | |
Allowable pressure difference(MPa) |
≤ Nominal pressure | |||||||||||||
Nominal pressure(MPa) | 10.0、16.0、25.0、32.0、45.0 | |||||||||||||
Rated route(mm) | 16 | 25 | 40 | 60 | 100 | |||||||||
Valve cover type | Standard type(-17~+250℃)、High temperature type(+250~+450℃) | |||||||||||||
Capping type | Bolt compression type | |||||||||||||
Seal packing | V type PTFE packing、V type flexible graphite filler | |||||||||||||
Valve core type | single seat Type、Cage Type | |||||||||||||
Flow characteristics | percentage | |||||||||||||
Configure Actuator series | 3810series、PSL series etc. Electric Actuator(Customers can also specify brands) | |||||||||||||
Actuator parameters | voltage:220V、input signal:4-20mAor1-5V·DC、output signal:4-20mA·DC | |||||||||||||
Protection level:Equivalent toIP65、Separate explosion levels:ExdⅡBT4(ExdⅡBT6Special custom)、Hand operation function:handle | ||||||||||||||
environment temperature:-25~+70℃、environment humidity:≤95% |
item | standard | ||
tolerance% | with3810L±2.5; withPSL±1.0 | ||
difference% | with381L ±2.0; withPSL±1.0 | ||
dead zone% | 1.0 | ||
tolerance between start point and end point% |
Electric open | start point±2.5 | end point±2.5 |
start point±2.5 | end point±2.5 | ||
Electric close | start point | ±2.5 | |
end point | ±2.5 | ||
Rated route tolerance % | ≤2.5 | ||
Leakage L/h | 0.01%×Valve rated capacity | ||
Adjustable range R | 30:1 |